1InstallationSENTROL ZX400/ZX410Security System Control
10Primary Zone and Secondary Zone Infinite Ohms 5.24 - 8.25 VOpen Contacts; Loop Cut or OpenSecondary Zone Open Contact, 1500 Ohms 4.24 - 5.23 VPrimar
11Class ‘B’ End-Of-Line ResistorSupervised ZonesA Class ‘B’ zone must be supervised with a 1500Ohm 1/2 Watt end-of-line resistor (P/N CR854). Thisres
12When unsupervised Control Stationsare used, ALL unsupervised LED Con-trol Stations must be addressed as 1or 2, ALL unsupervised SSD ControlStations
13No Control Station LED’s or display Black or Red Wire removed or cutNo response from key presses Green Wire removed or cut or two supervisedControl
143SW NEGAC XFMR4AUX125BELL62WS7NEG8DAT A9DAT B10KP+1211NEG12Z1/713Z2/814NEG15Z3/916Z4/1017NEG18Z5/1119Z6/1220NEG1 2ZX400/ZX410J1J3OUTPUTS1
15Outputs may be wired to indicator devices or re-lay module triggers (like the MPI-206) providedthe 40 mA current draw condition is not exceeded.Figu
16Expansion ZonesZones 13-28 are expansion zones. They may resideon any zone expansion device (ZXEXP, ZEM, RF Gate-way 1 or RF Gateway 2). Assignmen
17This module provides an additional 8 zones for theZX400/ZX410 Control. If “2 in 1” Zoning™ is de-sired, this module provides 16 zones. All zones are
18The ZX400/ZX410 provides an option for includingWireless (or RF) Devices.The RF Devices may consistof RF Zone Devices (Universals, Door Contacts,Gla
19FIRE ZONE MODULESFire Zone ModulesZEM Zone Expansion ModuleThe ZX400/ZX410 provides an option for addingClass B Fire zones. These zones may be conne
20FIRE ZONE MODULESZone 1 is shown with2-wire detectors,wired in Class B (Style B)2.7KEOL2.7KEOL2.7KEOLZone 4 is shown with 2-wireheat detectors and p
21FIRE ZONE MODULESNOTEB+B- B+ B- B+ B- B+ B-ZONE 1ZONE 2 ZONE 3 ZONE 4TB1POWERALARMZONE 1TRBLALARMZONE 2TRBLALARMZONE 3TRBLALARMZONE 4TRBLRELAY 1NCCO
22+-+-BATTERY BBATTERY ATo J10On The ZXCFMTo Bat. -On The ControlPOWER ISSUESITEM DESCRIPTIONSTANDBYCURRENTPER UNIT(AMPS)QTYTOTALSTANDBYCURRENTPER ITE
23POWER ISSUESAuxiliary Power Supply InstallationTo increase the available current supplied by thecontrol, a HCP-12SULC Power Supply may be added.Each
24ZXPTR Printer Interface ModuleZXPTR PRINTER INTERFACE MODULEThe optional ZXPTR Printer Interface Module con-nects to the local data bus and can be u
25Control Board• Six (6) two-wire zones, each supervised with a1500 Ohm end-of-line resistor. “2 in 1” Zon-ing™ provides twelve (12) fully programma
26• Two pager phone numbers, each can have upto 20 digits• Remote programming phone number can haveup to 20 digits.• Reporting capabilities: two 4-dig
27• ZXODM: Output Driver Module: Provides ten(10) fully programmable 40 mA + 12 VDC out-puts. Nominal current drain: 10 - 13 mA withno outputs con
28ESL Two-Wire Smoke Detectors429 AT, C, CT, CRT, CST: Standby Current: 70 µAmax. (Max. 20 detectors per zone)521 B, BXT, CRXT: Standby Current: 70 µA
29Agency RequirementsAGENCY REQUIREMENTSHome Health Care UL 1637 400 4 6 4 N/A UL listedHousehold Burglary UL 1023 signaling deviceHousehold Fire CSFM
3New Features... 5ZX400/ZX410 Wiring Diagram
30Household Burglary UL 1023Household Fire UL 985Household Burglary/Household Fire Combination UL 1023/UL 985Local Burglar Alarm Grades A, B and C Cen
31TestingThis system should be tested weekly. All switches,contacts, and accessories must be UL Listed devices.This equipment should be installed in
32SYSTEM TROUBLESHOOTINGAC FAILURE Indicates the loss of AC power or that the AC voltage is not high enough to power the system.ALARM SILENCED Indicat
33NOTESNotes__________________________________________________________________________________________________________________________________________
34Part 68 NotificationThis equipment complies with Part 68 of the Fed-eral Communications Commissions (FCC) rules. Allconnections to the telephone ne
35LimitationsThe ZX400/ZX410 is part of a system designed towarn against unauthorized entry or of other situa-tions. However, it is not a guarantee o
3664812692FSENTROLPO Box 2904, 1510 Tate Blvd. SEHickory, NC 28603Tel.: 503.692.4052 Fax: 503.691.7566U.S. & Canada: 800.547.2556Technical
4Specifications And Features ... 25Control Board ...
5The Sentrol ZX400/ZX410 Security Control featuresease of installation and programming. The ZX400/ZX410 is easily programmed with any one of fourCont
6See Specification and Features section for a complete list of compatible accessories.FIGURE 1 Suggested UL Household Burglar Alarm and/or Fire (ƒƒ
7FIGURE 2 Programmable Output And Telco Supervision Wiring DiagramZX400/ZX410 WIRING DIAGRAMS+12V NEGTG+TG - COM NC NOMPI-206TO TERMINAL 10TO TERM
81, 2 AC Input Connect the appropriate UL Class II transformer using 18 gauge minimum 2conductor wire. Do not exceed 50 feet. Use a 16.5 VAC 35 VA tr