Wheelock NS-1215W Spécifications

Naviguer en ligne ou télécharger Spécifications pour Détecteurs de fumée Wheelock NS-1215W. Wheelock NS-1215W Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Series

NetworX™ Series NX-8E-CF Control Panel Installation and Startup

Page 2 - SAFETY SYMBOL LEGEND

NX-8E-CF CONTROL 10  UL has only verified compatibility with the following listed DACRs and formats: Sure-Gard SG-MLR2-DG: 2,9,10,12,13,14; Silent K

Page 3 - Table of Contents

NX-8E-CF CONTROL 11TERM DESCRIPTION LOC PG BOX TAMPER The control panel has an input for a normally closed tamper switch (see terminal drawing). The

Page 4 - III. BOARD INSTALLATION

NX-8E-CF CONTROL 12 TERM DESCRIPTION LOC PG GROUP BYPASS A designated group of zones can be programmed to bypass by pressing [Bypass]- [0]-[Bypass]

Page 5

NX-8E-CF CONTROL 13TERM DESCRIPTION LOC PG TELEPHONE LINE MONITOR The NX-8E-CF has a Telephone Line Monitor that monitors the voltage and current of

Page 6 - IV. NX-8E-CF WIRING DIAGRAM

NX-8E-CF CONTROL 14 Shortcut keys:  Previous location.  Same location.  Next sequential location. BINARY DATA The top line of the d

Page 7 - V. TERMINAL DESCRIPTIONS

NX-8E-CF CONTROL 15X. ENROLLING MODULES AND KEYPADS For supervision purposes, the control panel has the ability to automatically find and store in i

Page 8 - ALARM HOURS

NX-8E-CF CONTROL 16 those partitions that should be reported to Phone #1. If no events should be reported to Phone #1, both locations should be pro

Page 9

NX-8E-CF CONTROL 17LOCATION 10 - EVENTS REPORTED TO PHONE #2 (2 segments of feature selection data) Segment 1: 1 = Alarms and Alarm Restores. 2 =

Page 10 - VIII. GLOSSARY

NX-8E-CF CONTROL 18 LOCATION 16 - EVENTS REPORTED TO PHONE #3 (2 segments, feature selection data) Segment 1: 1 = Alarms and Alarm Restores. 2 = O

Page 11 - NX-8E-CF CONTROL

NX-8E-CF CONTROL 19L LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data) Location 24 is used to program the Entry/Exit times. There are 2

Page 12

© 2005 GE Security All rights reserved. NetworX is a trademark of the GE companies. These instructions do not purport to cover all details or var

Page 13 - PROGRAMMING A LOCATION

NX-8E-CF CONTROL 20 DATA DESCRIPTION OF DEFAULT ZONE TYPES 21 GAS DETECTION- Creates an instant alarm regardless of the armed state of the control p

Page 14

NX-8E-CF CONTROL 21L LOCATION 31 - ZONES 25-32 ZONE TYPE GROUP (8 segments, numerical data) Location 31 contains the Zone Type for zones 25-32. Seg

Page 15 - L QUICK START INSTALLATION

NX-8E-CF CONTROL 22 Segment 4: 1 - On if Fail To Communicate report enabled. 2 - On if Log Full report enabled. 3 - On if Autotest report enabled. 4

Page 16

NX-8E-CF CONTROL 23LOCATION 41 - SPECIAL FEATURES (1 segment, feature selection data) Segment 1: 1 - On enables the 6-digit code option. If 6-dig

Page 17

NX-8E-CF CONTROL 24 LOCATION 47 - AUXILIARY OUTPUT #1, EVENT AND TIME (2 segments, numerical data) Segment 1: Use the chart on page 24 to select

Page 18

NX-8E-CF CONTROL 25LOCATION 53 - CLOSING TIME/AUTOMATIC ARMING TIME (2 segments, numerical data) Location 53 contains the time in 24 hour format the

Page 19

NX-8E-CF CONTROL 26 LOCATION 92 - ACCOUNT CODE FOR PARTITION 3 (6 segments, numerical data) The account code sent when partition 3 is reported is pr

Page 20

NX-8E-CF CONTROL 27LOCATION 102 - PARTITION 6 FEATURE AND REPORTING SELECTIONS (5 segments, feature selection data) Location 102 is used to enable c

Page 21

NX-8E-CF CONTROL 28 LOCATIONS 110-169 ARE USED TO CHANGE THE ZONE TYPES (Configurations) AS LISTED IN THE TABLE ON PAGE 19. THESE LOCATIONS ARE CONSI

Page 22

NX-8E-CF CONTROL 29LOCATION 117 - ZONE TYPE 4 CHARACTERISTIC SELECT (5 segments, feature selection data) Use "Zone Type Characteristic Selectio

Page 23

Table of Contents I. GENERAL DESCRIPTION ...

Page 24

NX-8E-CF CONTROL 30 LOCATION 137 - ZONE TYPE 14 CHARACTERISTIC SELECT (5 segments, feature selection data) Use "Zone Type Characteristic Selecti

Page 25

NX-8E-CF CONTROL 31LOCATION 156 - ZONE TYPE 24 ALARM EVENT CODE (1 segment, numerical data) Location 156 contains the event code sent for a Contact I

Page 26

NX-8E-CF CONTROL 32 LOCATION 173 - PARTITION SELECT, ZONES 57-64 (8 segments of feature selection data) Location 173 is used to select the partitio

Page 27

NX-8E-CF CONTROL 33LOCATION 183 - PARTITION SELECT, ZONES 97-104 (8 segments of feature selection data) Location 183 is used to select the partitio

Page 28

NX-8E-CF CONTROL 34 LOCATION 193 - PARTITION SELECT, ZONES 137-144 (8 segments of feature selection data) Location 193 is used to select the partit

Page 29

NX-8E-CF CONTROL 35LOCATION 203 - PARTITION SELECT, ZONES 177-184 (8 segments of feature selection data) Location 203 is used to select the partiti

Page 30

NX-8E-CF CONTROL 36 Segment 2: DATA ENABLES TRANSITION DATA ENABLES TRANSITION 1 System Status Message 4 Keypad Message Received 2 X-10 Messag

Page 31

NX-8E-CF CONTROL 37 XIV. PROGRAMMING WORKSHEETS (Factory defaults for segments are in bold italics text and "Quick Start" locations are id

Page 32

NX-8E-CF CONTROL 38 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA L23 18 PARTITION #1, FEATURE SELECTION Segment #1 1 = Quick Arm 2 = Re-Exit

Page 33

NX-8E-CF CONTROL 39 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA ZONES 25-32, PARTITION SELECTION (Segment 1=Zone 25 thru Segment 8=Zone 32) Seg

Page 34

NX-8E-CF CONTROL 4 I. GENERAL DESCRIPTION The NetworX NX-8E-CF represents a new approach to security systems design. Drawing on our experience in t

Page 35

NX-8E-CF CONTROL 40 LOC PG DESCRIPTION DEFAULT DATA L 38 22 SWINGER SHUTDOWN COUNT 0 _ L 39 22 KEYPAD SOUNDER CONTROL 1 = Keypad s

Page 36

NX-8E-CF CONTROL 41 LOC PG DESCRIPTION DEFAULT DATA 46 23 AUXILIARY OUTPUTS 1-4 SPECIAL TIMING Segments 1 2 3 4 Auxiliary output time

Page 37 - XIV. PROGRAMMING WORKSHEETS

NX-8E-CF CONTROL 42 LOC PG DESCRIPTION DEFAULT DATA PARTITION 2, FEATURE AND REPORTING SELECTION Segment #1 1 2 3 4 Quick Arm Re-Exit Auto Bypa

Page 38

NX-8E-CF CONTROL 43 LOC PG DESCRIPTION DEFAULT DATA 95 26 PARTITION 4, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _ PARTITION 4, FEATURE AN

Page 39

NX-8E-CF CONTROL 44 LOC PG DESCRIPTION DEFAULT DATA 102 27 PARTITION 6, FEATURE AND REPORTING SELECTION Segment #1 1 2 3 4 Quick Arm Re-Exit Au

Page 40

NX-8E-CF CONTROL 45 LOC PG DESCRIPTION DEFAULT DATA 108 27 PARTITION 8, FEATURE AND REPORTING SELECTION Segment #1 1 2 3 4 Quick Arm Re-E

Page 41

NX-8E-CF CONTROL 46 THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS 112-169 BELOW REPRESENT THE THREE SEGMENTS OF EACH OF THOSE LOCATIONS. USE THE

Page 42

NX-8E-CF CONTROL 47 LOC PG DESCRIPTION DEFAULT DATA L 170 31 ZONES 49-56, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _ ZONES 49-56, PARTITION

Page 43

NX-8E-CF CONTROL 48 LOC PG DESCRIPTION DEFAULT DATA L178 32 ZONES 81-88, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _ ZONES 81-88, PARTITION

Page 44

NX-8E-CF CONTROL 49 LOC PG DESCRIPTION DEFAULT DATA L186 33 ZONES 113-120, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _ ZONES 113-120, PARTIT

Page 45

NX-8E-CF CONTROL 5 K IMPORTANT! 1. If separate power supplies are necessary to accommodate additional devices, safety standards require that each po

Page 46

NX-8E-CF CONTROL 50 LOC PG DESCRIPTION DEFAULT DATA L194 34 ZONES 145-152, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _ ZONES 145-152, PARTIT

Page 47

NX-8E-CF CONTROL 51 LOC PG DESCRIPTION DEFAULT DATA L202 34 ZONES 177-184, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _ ZONES 177-184, PARTIT

Page 48

NX-8E-CF CONTROL 52 LOC PG DESCRIPTION DEFAULT DATA NX-584 COMMAND/REQUEST ENABLE Segment #1 Segment #2 1 = Reserved 2 = Interface Configuratio

Page 49

NX-8E-CF CONTROL 53 ZONE WORKSHEET 1 49 97 145 2 50 98 146 3 51 99 147 4 52 100 148 5 53 101 14

Page 50

NX-8E-CF CONTROL 54 XV. APPENDIX 1 REPORTING FIXED CODES IN CONTACT ID AND SIA The table lists the event codes sent for the following reports (if

Page 51 - 1 = System Status Message

NX-8E-CF CONTROL 55 XVI. APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID The NX-8E-CF has the ability to report SIA level 1 transmissions t

Page 52 - Segment #4

NX-8E-CF CONTROL 56 XVII. APPENDIX 3 REPORTING ZONE CODES IN CONTACT ID The NX-8E-CF has the ability to report Ademco Contact ID transmissions.

Page 53

NX-8E-CF CONTROL 57 XVIII. APPENDIX 4 EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE The tables below list the device numbers that will be reporte

Page 54 - XV. APPENDIX 1

NX-8E-CF CONTROL 58 XIX. TELEPHONE COMPANY INTERFACE INFORMATION TELEPHONE CONNECTION REQUIREMENTS Except for telephone company provided ringers, a

Page 55 - XVI. APPENDIX 2

NX-8E-CF CONTROL 59 XX. NOTICES (Applies to products which have the CE mark attached) DECLARATION OF CONFORMITY Manufacturer’s Name: Caddx Con

Page 56 - XVII. APPENDIX 3

NX-8E-CF CONTROL 6IV. NX-8E-CF WIRING DIAGRAM

Page 57 - XVIII. APPENDIX 4

XXI. SPECIFICATIONS OPERATING POWER 16.5 VAC, 50 VA Transformer AUXILIARY POWER w/ 50 VA Transformer 12 VDC Special Applications 1.2 A

Page 58 - INDUSTRY CANADA INFORMATION

NX-8E-CF CONTROL 7V. TERMINAL DESCRIPTIONS TERMINAL DESCRIPTION R1 House Telephone Ring (Grey). R Telephone Ring (Red). T Telephone Tip (Green

Page 59 - XX. NOTICES

NX-8E-CF CONTROL 8 VI. BATTERY CALCULATION WORKSHEET Note: The Total Standby or Total Alarm Current cannot exceed 1.2 Amps. Current for the sm

Page 60 - XXI. SPECIFICATIONS

NX-8E-CF CONTROL 9VII. UNDERWRITERS LABORATORIES INFORMATION The NetworX NX-8E-CF holds the following listings from Underwriters Laboratories (US a

Commentaires sur ces manuels