NetworX™ Series NX-8E-CF Control Panel Installation and Startup
NX-8E-CF CONTROL 10 UL has only verified compatibility with the following listed DACRs and formats: Sure-Gard SG-MLR2-DG: 2,9,10,12,13,14; Silent K
NX-8E-CF CONTROL 11TERM DESCRIPTION LOC PG BOX TAMPER The control panel has an input for a normally closed tamper switch (see terminal drawing). The
NX-8E-CF CONTROL 12 TERM DESCRIPTION LOC PG GROUP BYPASS A designated group of zones can be programmed to bypass by pressing [Bypass]- [0]-[Bypass]
NX-8E-CF CONTROL 13TERM DESCRIPTION LOC PG TELEPHONE LINE MONITOR The NX-8E-CF has a Telephone Line Monitor that monitors the voltage and current of
NX-8E-CF CONTROL 14 Shortcut keys: Previous location. Same location. Next sequential location. BINARY DATA The top line of the d
NX-8E-CF CONTROL 15X. ENROLLING MODULES AND KEYPADS For supervision purposes, the control panel has the ability to automatically find and store in i
NX-8E-CF CONTROL 16 those partitions that should be reported to Phone #1. If no events should be reported to Phone #1, both locations should be pro
NX-8E-CF CONTROL 17LOCATION 10 - EVENTS REPORTED TO PHONE #2 (2 segments of feature selection data) Segment 1: 1 = Alarms and Alarm Restores. 2 =
NX-8E-CF CONTROL 18 LOCATION 16 - EVENTS REPORTED TO PHONE #3 (2 segments, feature selection data) Segment 1: 1 = Alarms and Alarm Restores. 2 = O
NX-8E-CF CONTROL 19L LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data) Location 24 is used to program the Entry/Exit times. There are 2
© 2005 GE Security All rights reserved. NetworX is a trademark of the GE companies. These instructions do not purport to cover all details or var
NX-8E-CF CONTROL 20 DATA DESCRIPTION OF DEFAULT ZONE TYPES 21 GAS DETECTION- Creates an instant alarm regardless of the armed state of the control p
NX-8E-CF CONTROL 21L LOCATION 31 - ZONES 25-32 ZONE TYPE GROUP (8 segments, numerical data) Location 31 contains the Zone Type for zones 25-32. Seg
NX-8E-CF CONTROL 22 Segment 4: 1 - On if Fail To Communicate report enabled. 2 - On if Log Full report enabled. 3 - On if Autotest report enabled. 4
NX-8E-CF CONTROL 23LOCATION 41 - SPECIAL FEATURES (1 segment, feature selection data) Segment 1: 1 - On enables the 6-digit code option. If 6-dig
NX-8E-CF CONTROL 24 LOCATION 47 - AUXILIARY OUTPUT #1, EVENT AND TIME (2 segments, numerical data) Segment 1: Use the chart on page 24 to select
NX-8E-CF CONTROL 25LOCATION 53 - CLOSING TIME/AUTOMATIC ARMING TIME (2 segments, numerical data) Location 53 contains the time in 24 hour format the
NX-8E-CF CONTROL 26 LOCATION 92 - ACCOUNT CODE FOR PARTITION 3 (6 segments, numerical data) The account code sent when partition 3 is reported is pr
NX-8E-CF CONTROL 27LOCATION 102 - PARTITION 6 FEATURE AND REPORTING SELECTIONS (5 segments, feature selection data) Location 102 is used to enable c
NX-8E-CF CONTROL 28 LOCATIONS 110-169 ARE USED TO CHANGE THE ZONE TYPES (Configurations) AS LISTED IN THE TABLE ON PAGE 19. THESE LOCATIONS ARE CONSI
NX-8E-CF CONTROL 29LOCATION 117 - ZONE TYPE 4 CHARACTERISTIC SELECT (5 segments, feature selection data) Use "Zone Type Characteristic Selectio
Table of Contents I. GENERAL DESCRIPTION ...
NX-8E-CF CONTROL 30 LOCATION 137 - ZONE TYPE 14 CHARACTERISTIC SELECT (5 segments, feature selection data) Use "Zone Type Characteristic Selecti
NX-8E-CF CONTROL 31LOCATION 156 - ZONE TYPE 24 ALARM EVENT CODE (1 segment, numerical data) Location 156 contains the event code sent for a Contact I
NX-8E-CF CONTROL 32 LOCATION 173 - PARTITION SELECT, ZONES 57-64 (8 segments of feature selection data) Location 173 is used to select the partitio
NX-8E-CF CONTROL 33LOCATION 183 - PARTITION SELECT, ZONES 97-104 (8 segments of feature selection data) Location 183 is used to select the partitio
NX-8E-CF CONTROL 34 LOCATION 193 - PARTITION SELECT, ZONES 137-144 (8 segments of feature selection data) Location 193 is used to select the partit
NX-8E-CF CONTROL 35LOCATION 203 - PARTITION SELECT, ZONES 177-184 (8 segments of feature selection data) Location 203 is used to select the partiti
NX-8E-CF CONTROL 36 Segment 2: DATA ENABLES TRANSITION DATA ENABLES TRANSITION 1 System Status Message 4 Keypad Message Received 2 X-10 Messag
NX-8E-CF CONTROL 37 XIV. PROGRAMMING WORKSHEETS (Factory defaults for segments are in bold italics text and "Quick Start" locations are id
NX-8E-CF CONTROL 38 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA L23 18 PARTITION #1, FEATURE SELECTION Segment #1 1 = Quick Arm 2 = Re-Exit
NX-8E-CF CONTROL 39 LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA ZONES 25-32, PARTITION SELECTION (Segment 1=Zone 25 thru Segment 8=Zone 32) Seg
NX-8E-CF CONTROL 4 I. GENERAL DESCRIPTION The NetworX NX-8E-CF represents a new approach to security systems design. Drawing on our experience in t
NX-8E-CF CONTROL 40 LOC PG DESCRIPTION DEFAULT DATA L 38 22 SWINGER SHUTDOWN COUNT 0 _ L 39 22 KEYPAD SOUNDER CONTROL 1 = Keypad s
NX-8E-CF CONTROL 41 LOC PG DESCRIPTION DEFAULT DATA 46 23 AUXILIARY OUTPUTS 1-4 SPECIAL TIMING Segments 1 2 3 4 Auxiliary output time
NX-8E-CF CONTROL 42 LOC PG DESCRIPTION DEFAULT DATA PARTITION 2, FEATURE AND REPORTING SELECTION Segment #1 1 2 3 4 Quick Arm Re-Exit Auto Bypa
NX-8E-CF CONTROL 43 LOC PG DESCRIPTION DEFAULT DATA 95 26 PARTITION 4, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _ PARTITION 4, FEATURE AN
NX-8E-CF CONTROL 44 LOC PG DESCRIPTION DEFAULT DATA 102 27 PARTITION 6, FEATURE AND REPORTING SELECTION Segment #1 1 2 3 4 Quick Arm Re-Exit Au
NX-8E-CF CONTROL 45 LOC PG DESCRIPTION DEFAULT DATA 108 27 PARTITION 8, FEATURE AND REPORTING SELECTION Segment #1 1 2 3 4 Quick Arm Re-E
NX-8E-CF CONTROL 46 THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS 112-169 BELOW REPRESENT THE THREE SEGMENTS OF EACH OF THOSE LOCATIONS. USE THE
NX-8E-CF CONTROL 47 LOC PG DESCRIPTION DEFAULT DATA L 170 31 ZONES 49-56, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _ ZONES 49-56, PARTITION
NX-8E-CF CONTROL 48 LOC PG DESCRIPTION DEFAULT DATA L178 32 ZONES 81-88, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _ ZONES 81-88, PARTITION
NX-8E-CF CONTROL 49 LOC PG DESCRIPTION DEFAULT DATA L186 33 ZONES 113-120, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _ ZONES 113-120, PARTIT
NX-8E-CF CONTROL 5 K IMPORTANT! 1. If separate power supplies are necessary to accommodate additional devices, safety standards require that each po
NX-8E-CF CONTROL 50 LOC PG DESCRIPTION DEFAULT DATA L194 34 ZONES 145-152, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _ ZONES 145-152, PARTIT
NX-8E-CF CONTROL 51 LOC PG DESCRIPTION DEFAULT DATA L202 34 ZONES 177-184, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _ ZONES 177-184, PARTIT
NX-8E-CF CONTROL 52 LOC PG DESCRIPTION DEFAULT DATA NX-584 COMMAND/REQUEST ENABLE Segment #1 Segment #2 1 = Reserved 2 = Interface Configuratio
NX-8E-CF CONTROL 53 ZONE WORKSHEET 1 49 97 145 2 50 98 146 3 51 99 147 4 52 100 148 5 53 101 14
NX-8E-CF CONTROL 54 XV. APPENDIX 1 REPORTING FIXED CODES IN CONTACT ID AND SIA The table lists the event codes sent for the following reports (if
NX-8E-CF CONTROL 55 XVI. APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID The NX-8E-CF has the ability to report SIA level 1 transmissions t
NX-8E-CF CONTROL 56 XVII. APPENDIX 3 REPORTING ZONE CODES IN CONTACT ID The NX-8E-CF has the ability to report Ademco Contact ID transmissions.
NX-8E-CF CONTROL 57 XVIII. APPENDIX 4 EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE The tables below list the device numbers that will be reporte
NX-8E-CF CONTROL 58 XIX. TELEPHONE COMPANY INTERFACE INFORMATION TELEPHONE CONNECTION REQUIREMENTS Except for telephone company provided ringers, a
NX-8E-CF CONTROL 59 XX. NOTICES (Applies to products which have the CE mark attached) DECLARATION OF CONFORMITY Manufacturer’s Name: Caddx Con
NX-8E-CF CONTROL 6IV. NX-8E-CF WIRING DIAGRAM
XXI. SPECIFICATIONS OPERATING POWER 16.5 VAC, 50 VA Transformer AUXILIARY POWER w/ 50 VA Transformer 12 VDC Special Applications 1.2 A
NX-8E-CF CONTROL 7V. TERMINAL DESCRIPTIONS TERMINAL DESCRIPTION R1 House Telephone Ring (Grey). R Telephone Ring (Red). T Telephone Tip (Green
NX-8E-CF CONTROL 8 VI. BATTERY CALCULATION WORKSHEET Note: The Total Standby or Total Alarm Current cannot exceed 1.2 Amps. Current for the sm
NX-8E-CF CONTROL 9VII. UNDERWRITERS LABORATORIES INFORMATION The NetworX NX-8E-CF holds the following listings from Underwriters Laboratories (US a
Commentaires sur ces manuels